OFS-2000F Flare Sensor
Optical flow velocity sensing for flare lines and flare stacks — EPA-approved for Subpart J & Ja, 0.03–170 m/s with a single sensor.
OFS-2000F Flare Sensor
Optical flow velocity sensing for flare lines and flare stacks — EPA-approved for Subpart J & Ja, 0.03–170 m/s with a single sensor.
- Fits both flare lines and flare stacks — one sensor covers background and emergency relief flow
- EPA-approved for Subpart Ja flare gas service under ALT-099, Approval of Optical Flow Meters for Flares
- No re-piping — 2 diameters upstream / 1 down instead of the 30-diameter runs ultrasonics need
- Hydrogen-rich streams are no problem — measurement is independent of molecular weight, temperature and pressure
- Monitors air-assist and steam-assist lines for MACT RSR combustion-zone dilution reporting
- Hot-tap installation on mating flanges — no unit shutdown required
Technical specifications
Headline operating envelope for the OFS-2000F Flare Sensor. Full datasheets and certificates of compliance are issued with the quote.
What ships with every OFS-2000F Flare Sensor
- ISO 9001:2015 calibration certificate
- Full factory acceptance test report
- Operator and integration manual
- Engineering support from the OSI design team
Certifications on file
Downloadable certificates and approval letters that apply to the OFS-2000F Flare Sensor.
- EPA Subpart J & Ja — ALT-099 — U.S. Environmental Protection Agency
- EPA MACT RSR 40 CFR 63.670 — Petroleum Refinery Sector Risk & Technology Review
- UL, CSA & IEC certificate of conformance — Entela (now ETL SEMKO, Intertek Group plc)
- NIST-traceable calibration standard — Optical Scientific, Inc.
Product brochure
Other emissions flow monitoring
RelatedFAQ — OFS-2000F Flare Sensor
Good to KnowThe OFS series is compliant with EPA Method 14, MACT RSR 40 CFR 63.670, CFR Part 75 (Acid Rain), and SCAQMD Rule 1118. Full Method 14 reporting packages are part of the OFS engineering deliverable.
The OFS-2000W variant is engineered for wet scrubbers and saturated, droplet-laden gas streams. It uses heated air-purge windows and a tuned DSP to maintain accuracy in conditions that defeat ultrasonic and thermal flow meters.
No. The OFS is non-intrusive — there are no probes in the gas stream, no pressure drop, no maintenance access to the stack interior.
Request a quote for the OFS-2000F Flare Sensor.
Send us a brief about the deployment — our engineering team will spec and price it within one business day.
- Engineering response within one business day
- Custom integration and OEM programs welcome
- 40+ years of optical sensing heritage behind every quote